LEM Stromsensoren
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Filter anzeigen
Filter zurücksetzen
Filter anwenden
KategorieSensoren / Stromsensoren / Stromsensoren
HerstellerLEM USA Inc.
Datensätze 359
Seite 11/12
Bild |
Teilenummer |
Hersteller |
Beschreibung |
Auf Lager |
Menge |
Serie | Zum Messen | Sensortyp | Stromerfassung | Anzahl der Kanäle | Ausgabe | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Stromversorgung (max.) | Betriebstemperatur | Polarisation | Montagetyp | Paket / Fall | Lieferantengerätepaket |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LEM |
SENSOR CURRENT HALL 1500A AC/DC |
1.511 |
|
HAT | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 15mA | -40°C ~ 105°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT FLUX 400MA AC/DC |
6.714 |
|
CT | AC/DC | Flux Gate, Closed Loop | 400mA | 1 | Ratiometric, Voltage | - | DC ~ 18kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT FLUX 200MA AC/DC |
6.912 |
|
CT | AC/DC | Flux Gate, Closed Loop | 200mA | 1 | Ratiometric, Voltage | - | DC ~ 7kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 300A AC/DC |
3.598 |
|
HTA | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | ±15V | 3µs | 25mA | -25°C ~ 85°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT XFMR 100A AC |
5.274 |
|
AT | AC | Transformer w/Conditioning | 100A | 1 | Ratiometric, 4mA ~ 20mA | - | 50/60Hz | ±0.5% | ±1.5% | 20V ~ 30V | 100ms | - | -20°C ~ 60°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 500A AC/DC |
6.480 |
|
HAX | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 600A AC/DC |
8.226 |
|
HAX | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 50A AC/DC |
3.438 |
|
HAL | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | ±15V | 3µs | 25mA | -25°C ~ 85°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT FLUX 200MA AC/DC |
5.130 |
|
CT | AC/DC | Flux Gate, Closed Loop | 200mA | 1 | Ratiometric, Voltage | - | DC ~ 11kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT XFMR 150A AC |
6.768 |
|
AT | AC | Transformer w/Conditioning | 150A | 1 | Ratiometric, 4mA ~ 20mA | - | 50/60Hz | ±0.5% | ±1.5% | 20V ~ 30V | 100ms | 30mA | -20°C ~ 60°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 50A AC/DC |
5.770 |
|
LA | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.15% | ±0.65% | ±12V ~ 15V | 1µs | 35mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 300A AC/DC |
141 |
|
LF | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | 12V ~ 20V | 1µs | 176mA | -40°C ~ 85°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 200A AC/DC |
8.460 |
|
DHR | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, 0 V ~ 5 V | - | DC ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | Bidirectional | Panel Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 100A AC/DC |
8.046 |
|
HAC | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 7µs | 18mA | -10°C ~ 80°C | Bidirectional | Panel Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 1000A AC/DC |
6.354 |
|
HTA | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | ±15V | 3µs | 25mA | -25°C ~ 85°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 300A AC/DC |
6.192 |
|
LF | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±12V ~ 15V | 1µs | 170mA | -25°C ~ 70°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 1500A AC/DC |
6.714 |
|
HAX | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
CUR TRANSDUCER, CLO LOOP,2000a |
1.180 |
|
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
LEM |
SENSOR CURRENT 50A, 75A, 100A |
3.186 |
|
APR | AC | Transformer w/Conditioning | 50A, 75A, 100A (Selectable) | 1 | Ratiometric, Voltage (Selectable) | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 24V | 400ms | 30mA | -20°C ~ 60°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT 10A, 25A, 50A |
7.470 |
|
APR | AC | Transformer w/Conditioning | 10A, 25A, 50A (Selectable) | 1 | Ratiometric, Voltage (Selectable) | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 24V | 400ms | 30mA | -20°C ~ 60°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT 100A, 150A, 200A |
6.354 |
|
APR | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, Voltage (Selectable) | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 24V | 400ms | 30mA | -20°C ~ 60°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 300A AC/DC |
6.588 |
|
LA | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.8% | ±12V ~ 15V | 1µs | 140mA | 0°C ~ 85°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 2000A AC/DC |
7.452 |
|
HAX | AC/DC | Hall Effect, Open Loop | 2000A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 300A AC/DC |
4.230 |
|
HTR | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 10kHz | ±1% | ±2% | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT 200A, 300A, 400A |
2.412 |
|
APR | AC | Transformer w/Conditioning | 200A, 300A, 400A (Selectable) | 1 | Ratiometric, Voltage (Selectable) | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 24V | 400ms | 30mA | -20°C ~ 60°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT 200A, 300A, 400A |
5.418 |
|
APR | AC | Transformer w/Conditioning | 200A, 300A, 400A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 12V ~ 24V | 400ms | 25mA | -20°C ~ 60°C | Bidirectional | Chassis Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 1000A AC/DC |
174 |
|
HAX | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | Bidirectional | Panel Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 200A AC/DC |
3.618 |
|
DHR | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, 0 V ~ 10 V | - | DC ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | Bidirectional | Panel Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 100A AC/DC |
4.662 |
|
DHR | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, 0 V ~ 5 V | - | DC ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | Bidirectional | Panel Mount | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 500A AC/DC |
8.226 |
|
DHR | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, 0 V ~ 5 V | - | DC ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | Bidirectional | Panel Mount | Module | - |