Leistungsschalter
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Filter anzeigen
Filter zurücksetzen
Filter anwenden
KategorieLeistung / Schaltungsschutz / Leistungsschalter
Datensätze 42.170
Seite 637/1406
Bild |
Teilenummer |
Hersteller |
Beschreibung |
Auf Lager |
Menge |
Serie | Unterbrechertyp | Nennstrom (Ampere) | Nennspannung - AC | Nennspannung - DC | Anzahl der Pole | Aktuatortyp | Beleuchtung | Beleuchtungsspannung (nominal) | Montagetyp | Zulassungen |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
E-T-A |
CIR BRKR 300MA 120VAC 60VDC |
7.920 |
|
808 | Magnetic (Hydraulic Delay) | 300mA | 120V | 60V | 1 | Push-Pull Plunger | - | - | Through Hole | CSA C22.2 No 235, UL1077 |
|
![]() |
E-T-A |
CIR BRKR 400MA 120VAC 60VDC |
7.434 |
|
808 | Magnetic (Hydraulic Delay) | 400mA | 120V | 60V | 1 | Push-Pull Plunger | - | - | Through Hole | CSA C22.2 No 235, UL1077 |
|
![]() |
E-T-A |
CIR BRKR 500MA 120VAC 60VDC |
8.874 |
|
808 | Magnetic (Hydraulic Delay) | 500mA | 120V | 60V | 1 | Push-Pull Plunger | - | - | Through Hole | CSA C22.2 No 235, UL1077 |
|
![]() |
E-T-A |
CIR BRKR 800MA 120VAC 60VDC |
5.562 |
|
808 | Magnetic (Hydraulic Delay) | 800mA | 120V | 60V | 1 | Push-Pull Plunger | - | - | Through Hole | CSA C22.2 No 235, UL1077 |
|
![]() |
E-T-A |
CIR BRKR MAGHYDR 2A 120VAC 60VDC |
2.484 |
|
808 | Magnetic (Hydraulic Delay) | 2A | 120V | 60V | 1 | Push-Pull Plunger | - | - | Through Hole | CSA C22.2 No 235, UL1077 |
|
![]() |
E-T-A |
CIR BRKR MAGHYDR 5A 120VAC 60VDC |
8.388 |
|
808 | Magnetic (Hydraulic Delay) | 5A | 120V | 60V | 1 | Push-Pull Plunger | - | - | Through Hole | CSA C22.2 No 235, UL1077 |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER |
3.132 |
|
LEL | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER |
6.372 |
|
LEL | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
TE Connectivity Potter & Brumfield Relays |
CIR BRKR MAG-HYDR 5A 415VAC |
7.182 |
|
W6 | Magnetic (Hydraulic Delay) | 5A | 415V | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
TE Connectivity Potter & Brumfield Relays |
CIR BRKR MAG-HYDR 20A 277VAC |
6.750 |
|
W9 | Magnetic (Hydraulic Delay) | 20A | 277V | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER |
6.732 |
|
LEL | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR ROCKER |
8.082 |
|
IEG | Magnetic (Hydraulic Delay) | - | - | - | 2 | Rocker | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIRCUIT BREAKER MAG-HYDR TOGGLE |
2.412 |
|
IAL | Magnetic (Hydraulic Delay) | - | - | - | 1 | Toggle | - | - | Panel Mount | - |
|
![]() |
E-T-A |
CIRC BRKR THRM |
7.974 |
|
3120-F | Thermal | 6A | 250V | 50V | 3 | Rocker | None | - | Panel Mount | - |
|
![]() |
E-T-A |
CIRC BRKR THRM |
4.554 |
|
3120-F | Thermal | 6A | 250V | 50V | 3 | Rocker | None | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR ROCKER |
5.220 |
|
IUG | Magnetic (Hydraulic Delay) | - | - | - | 2 | Rocker | - | - | Panel Mount | - |
|
![]() |
Carling Technologies |
CIR BRKR 15A 480VAC 80VDC |
8.010 |
|
C | Magnetic (Hydraulic Delay) | 15A | 480V | 80V | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER |
5.076 |
|
LML | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
E-T-A |
CIR BRKR THRM 2.5A 250VAC 50VDC |
7.506 |
|
3120-F | Thermal | 2.5A | 250V | 50V | 2 | Rocker | Green | 90V | Panel Mount | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
![]() |
E-T-A |
CIR BRKR THRM 5A 250VAC 50VDC |
8.766 |
|
3120-F | Thermal | 5A | 250V | 50V | 2 | Rocker | Green | 90V | Panel Mount | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
![]() |
E-T-A |
CIR BRKR THRM 2.5A 250VAC 50VDC |
8.928 |
|
3120-F | Thermal | 2.5A | 250V | 50V | 2 | Rocker | Green | 185V | Panel Mount | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
![]() |
E-T-A |
CIR BRKR THRM 12A |
4.464 |
|
3120-F | Thermal | 12A | 250V | 50V | 2 | Rocker | Green | 90V | Panel Mount | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
![]() |
E-T-A |
CIR BRKR THRM 4A |
4.608 |
|
3120-F | Thermal | 4A | 250V | 50V | 2 | Rocker | - | - | Panel Mount | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER |
5.364 |
|
IAG | Magnetic (Hydraulic Delay) | - | - | - | - | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR ROCKER |
2.952 |
|
IEG | Magnetic (Hydraulic Delay) | - | - | - | 2 | Rocker | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR ROCKER |
4.176 |
|
IEG | Magnetic (Hydraulic Delay) | - | - | - | 2 | Rocker | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR ROCKER |
6.426 |
|
IEG | Magnetic (Hydraulic Delay) | - | - | - | 2 | Rocker | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR ROCKER |
3.726 |
|
IEG | Magnetic (Hydraulic Delay) | - | - | - | 2 | Rocker | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR ROCKER |
2.304 |
|
IEG | Magnetic (Hydraulic Delay) | - | - | - | 2 | Rocker | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIRCUIT BREAKER MAG-HYDR LEVER |
5.742 |
|
IUL | Magnetic (Hydraulic Delay) | - | - | - | - | Lever | - | - | Panel Mount | - |