KategorieLeistung / Schaltungsschutz / Leistungsschalter
Datensätze 42.170
Seite 533/1406
Bild |
Teilenummer |
Hersteller |
Beschreibung |
Auf Lager |
Menge |
Serie | Unterbrechertyp | Nennstrom (Ampere) | Nennspannung - AC | Nennspannung - DC | Anzahl der Pole | Aktuatortyp | Beleuchtung | Beleuchtungsspannung (nominal) | Montagetyp | Zulassungen |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER |
3.438 |
|
IUG | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER |
6.534 |
|
IUG | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER |
6.858 |
|
IUG | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER |
3.762 |
|
IUG | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIRCUIT BREAKER MAG-HYDR LEVER |
7.524 |
|
IEL | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIRCUIT BREAKER MAG-HYDR LEVER |
8.442 |
|
IEL | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIRCUIT BREAKER MAG-HYDR LEVER |
5.580 |
|
IEL | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIRCUIT BREAKER MAG-HYDR LEVER |
5.112 |
|
IEL | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIRCUIT BREAKER MAG-HYDR LEVER |
4.842 |
|
IEL | Magnetic (Hydraulic Delay) | - | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIRCUIT BREAKER MAG-HYDR LEVER |
6.966 |
|
* | - | - | - | - | - | - | - | - | - | - |
|
![]() |
Sensata-Airpax |
CIRCUIT BREAKER MAG-HYDR LEVER |
2.142 |
|
* | - | - | - | - | - | - | - | - | - | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 15A ROCKER |
4.230 |
|
LEL | Magnetic (Hydraulic Delay) | 15A | - | - | 1 | Rocker | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR ROCKER |
2.736 |
|
CEG | Magnetic (Hydraulic Delay) | - | - | - | - | Rocker | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER |
6.984 |
|
IAG | Magnetic (Hydraulic Delay) | - | - | - | - | Lever | - | - | Panel Mount | - |
|
![]() |
E-T-A |
CIR BRKR THRM 16A 250VAC 50VDC |
6.480 |
|
3120-F | Thermal | 16A | 250V | 50V | 2 | Rocker | - | - | Panel Mount | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
![]() |
E-T-A |
CIR BRKR THRM 6A 250VAC 50VDC |
4.734 |
|
3120-F | Thermal | 6A | 250V | 50V | 2 | Rocker | - | - | Panel Mount | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
![]() |
E-T-A |
CIR BRKR THRM 3A 250VAC 50VDC |
3.438 |
|
3120-F | Thermal | 3A | 250V | 50V | 2 | Rocker | - | - | Panel Mount | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER 10A |
3.006 |
|
IUG | Magnetic (Hydraulic Delay) | 10A | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER 5A |
6.588 |
|
IUG | Magnetic (Hydraulic Delay) | 5A | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 14A |
3.636 |
|
IAL | Magnetic (Hydraulic Delay) | 14A | - | - | 1 | Rocker | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 4A TOGGLE |
6.534 |
|
IUG | Magnetic (Hydraulic Delay) | 4A | - | - | 1 | Toggle | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 5A LEVER |
3.816 |
|
IUL | Magnetic (Hydraulic Delay) | 5A | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 10A LEVER |
7.974 |
|
IUL | Magnetic (Hydraulic Delay) | 10A | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 20A LEVER |
3.580 |
|
IUL | Magnetic (Hydraulic Delay) | 20A | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 40A LEVER |
4.086 |
|
IUL | Magnetic (Hydraulic Delay) | 40A | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 2A LEVER |
7.758 |
|
LEJ | Magnetic (Hydraulic Delay) | 2A | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 20A LEVER |
2.754 |
|
LEJ | Magnetic (Hydraulic Delay) | 20A | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR |
5.616 |
|
LEJ | Magnetic (Hydraulic Delay) | 15A | 240V | - | 2 | Lever | None | - | Panel Mount | - |
|
![]() |
E-T-A |
CIR BRKR THRM 30A 250VAC 50VDC |
8.244 |
|
127 | Thermal | 30A | 250V | 50V | 1 | Push to Reset | - | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
![]() |
E-T-A |
CIR BRKR THRM 10A 250VAC 50VDC |
4.212 |
|
127 | Thermal | 10A | 250V | 50V | 1 | Push to Reset | - | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |